Introduction
NSCAFragment
SystemMonitorNotification / Notification / NotificationMonitor / NotificationInterface
NSCA plug-in Interface to be executed for System Monitor notification.
NotificationInterface
supports the following attributes:
Attribute | Usage | Description |
---|---|---|
monitor_host | Required | This setting specifies the host name or ip address of System Monitor host. |
monitor_port | Required | This setting specifies the TCP port that the System Monitor would listen to. |
monitor_password | Optional | This setting specifies the password
|
monitor_connection_timeout | Optional | This setting specifies the connection timeout in ms. Default: |
monitor_response_timeout | Optional | This setting specifies the response timeout in ms. |
monitor_encryption | Optional | This setting specifies that the communication with the System Monitor is encrypted. By default no encryption is used.
|
service_host | Required | This setting specifies the name of the host that executes the passive check. The name must match the corresponding setting in the System Monitor. |
plugin | Optional | Default:
|
System Monitor: Opsview
In case you are using Opsview® as a monitoring tool consider that the plugin will not work, since Opsview® supports ca. 20 encryption types that are not supported by this plugin. You could only use it in case you use no encryption (type: NONE) for connections to Opsview®.
Instead, you should use the XML CommandFragment
element and indicate the exact command to send passive checks to Opsview® from a remote machine (see example for op5 or example for zabbix).