Introduction

NSCAFragment


SystemMonitorNotification / Notification / NotificationMonitor / NotificationInterface

NSCA plug-in Interface to be executed for System Monitor notification.

NotificationInterface supports the following attributes:

AttributeUsageDescription
monitor_hostRequiredThis setting specifies the host name or ip address of System Monitor host.
monitor_portRequiredThis setting specifies the TCP port that the System Monitor would listen to.
monitor_passwordOptional

This setting specifies the password

  • for NSCA - password configured in the ncsa.cfg file.
monitor_connection_timeoutOptional

This setting specifies the connection timeout in ms.

Default: 5000

monitor_response_timeoutOptionalThis setting specifies the response timeout in ms.
monitor_encryptionOptional

This setting specifies that the communication with the System Monitor is encrypted. By default no encryption is used.

  • NONE             - no encryption
  • XOR            - XOR encryption
  • TRIPLE_DES - use of triple des algorithm for encryption
service_hostRequiredThis setting specifies the name of the host that executes the passive check. The name must match the corresponding setting in the System Monitor.
pluginOptional

Default:

    • JobScheduler releases before 1.11

      • com.sos.scheduler.notification.plugins.notifier.SystemNotifierSendNscaPlugin
    • JobScheduler releases starting from 1.11

      • com.sos.jitl.notification.plugins.notifier.SystemNotifierSendNscaPlugin

See : Message, Examples

Example
...
<NotificationInterface monitor_host="monitor_host" monitor_port="5667" monitor_encryption="XOR" service_host="service_host"><![CDATA[
scheduler id=${MON_N_SCHEDULER_ID}, history id=${MON_N_ORDER_HISTORY_ID}, job_chain=${MON_N_JOB_CHAIN_NAME}(${MON_N_ORDER_ID}), step =${MON_N_ORDER_STEP_STATE}, error=${MON_N_ERROR_TEXT}
]]></NotificationInterface>
...

System Monitor: Opsview

In case you are using Opsview® as a monitoring tool consider that the plugin will not work, since Opsview® supports ca. 20 encryption types that are not supported by this plugin. You could only use it in case you use no encryption (type: NONE) for connections to Opsview®.

Instead, you should use the XML  CommandFragment element and indicate the exact command to send passive checks to Opsview® from a remote machine (see example for op5 or example for zabbix).