Installation Errors
Installer raises error "Validating data
for panel jetty was not successful"
Observation
A user tries to install JOC Cockpit, but gets an error as below:
[scheduler@jos11rc2 joc.1.11.0-RC2]$ ./setup.sh -u joc_install.xml
java -Dizpack.mode=privileged -jar "./joc.1.11.0-RC2.jar" joc_install.xml
[ Starting automated installation ]
numOfPrevInstallations=0
com.izforge.izpack.installer.InstallerException: Validating data
for panel jetty was not successful
com.izforge.izpack.installer.InstallerException: Validating data
for panel jetty was not successful
at com.izforge.izpack.installer.AutomatedInstaller.validatePanel(Unknown
Source)
at com.izforge.izpack.installer.AutomatedInstaller.installPanel(Unknown
Source)
at com.izforge.izpack.installer.AutomatedInstaller.doInstall(Unknown
Source)
at com.izforge.izpack.installer.Installer.main(Unknown Source) [
Automated installation FAILED! ]
Explanation
By using the -u
switch the user requested the installer not to switch to the root
account in order to acquire privileges that allow to create folders. At the same time the user scheduler
does not have the permissions to create a folder in the /opt/sos-berlin.com
directory.
Admittedly the error message that is presented by IZPack installer is confusing, however, missing permissions are the cause for this error.
Use ./setup.sh joc_install.xml
without the -u
switch to install JOC Cockpit with correct permissions.
JOC Cockpit Windows Service does not start
Observation
A user tries to install the JOC Cockpit and gets an error when tryng to start the Windows service.
+------------------------------------------------------------------------------------------------------------------------
| Start Jetty service for JOC (JobScheduler Operations Center)
+------------------------------------------------------------------------------------------------------------------------
Le service SOS JOC (JobScheduler Operations Center) démarre.
Le service SOS JOC (JobScheduler Operations Center) n'a pas pu êté lancé
Une erreur spécifique … un service s'est produit: 5.
Vous obtiendrez une aide supplémentaire en entrant NET HELPMSG 3547.
The log file joc.YYYY-MM-DD.log
shows the following information:
[2016-12-26 14:08:11] [info] [10424] Commons Daemon procrun (1.0.15.0 32-bit) started
[2016-12-26 14:08:11] [info] [10424] Service sos_joc name SOS JOC (JobScheduler Operations Center)
[2016-12-26 14:08:12] [info] [10424] Service 'sos_joc' installed
[2016-12-26 14:08:12] [info] [10424] Commons Daemon procrun finished
[2016-12-26 14:08:12] [info] [8708] Commons Daemon procrun (1.0.15.0 32-bit) started
[2016-12-26 14:08:12] [info] [8708] Running 'sos_joc' Service ...
[2016-12-26 14:08:12] [info] [3988] Starting service ...
[2016-12-26 14:08:13] [error] [3988] Failed to execute process
[2016-12-26 14:08:13] [error] [3988] Invalid directory name.
[2016-12-26 14:08:13] [error] [3988] ServiceStart returned 5
[2016-12-26 14:08:13] [error] [3988] Invalid directory name.
[2016-12-26 14:08:13] [info] [8708] Run service finished.
Explanation
The Windows Service tries to locate the Java Virtual Machine from a non-existing directory. This happens due to the fact that the JVM is not found from the PATH
- as e.g. the installer - but from the Windows Registry or JAVA_HOME
environment variable. If the JAVA_HOME
environment variable points to a non-existent directory then the above error "Invalid directory name
" is raised and the Windows Service will not tart.
Operations Errors
Database Connection to MySQL unavailable after idle timeout
If a MySQL DBMS is being used by the JobScheduler, then the MySQL wait_timeout
that rules the max. lifetime of idle connections should be checked and if necessary modified.
- The default
wait_timeout
for MySQL is relatively short and the JOC Cockpit does not have a mechanism for keeping the connection open over longer periods of time such as overnight. - See the following article for instructions about how to change the MySQL DBMS timeout variable:
- If the DBMS
wait_timeout
is too short users will get an "Unauthorized to access JOC Cockpit" message together with a JOC-407 error message after submitting their credentials. However, restarting the JOC Cockpit web service / daemon will create a new database connection and allow authorized users to log in again.