languagetext
titleUsage for Unix
Usage: agent.sh command [options] [switches]
  command:
    start           [options]
    start-container [options]
    stop            [options]
    restart         [options]
    status          [options]
    cancel          [options]
    cert            [cert-options]         | see https://kb.sos-berlin.com/x/jLbAAw
  options:
    --http-port=<[interface:]port>         | http network interface and port, default: 4445
    --https-port=<[interface:]port>        | https network interface and port, default:
    --data-directory=<directory>           | default: /var/sos-berlin.com/js7/agent/var_4445
    --config-directory=<directory>         | default: /var/sos-berlin.com/js7/agent/var_4445/config
    --sigkill-delay=<seconds>              | send SIGTERM and delayed SIGKILL signal, default: 3
    --timeout=<seconds>                    | timeout for terminating jobs on Agent stop
    --java-options=<java options>          | default: -Xms100m -Dfile.encoding=UTF-8; see https://kb.sos-berlin.com/x/uYo7B
  switches: 
    -c | --curl                            | use curl instead of Java http client

see https://kb.sos-berlin.com/x/ZqrAAw for more information.

...

Code Block
languagetext
titleUsage for Windows
Usage: agent.cmd command [options] [switches] 
  command:
    start           [options]
    start-container [options]
    stop            [options]
    restart         [options]
    status          [options]
    cancel          [options]
    cert            [cert-options]         | see https://kb.sos-berlin.com/x/jLbAAw
  options:
    --http-port=<[interface:]port>         | http network interface and port, default: 4445
    --https-port=<[interface:]port>        | https network interface and port, default:
    --data-directory=<directory>           | default: /var/sos-berlin.com/js7/agent/var_4445
    --config-directory=<directory>         | default: /var/sos-berlin.com/js7/agent/var_4445/config
    --timeout=<seconds>                    | timeout for terminating jobs on Agent stop
    --java-options=<java options>          | default: -Xms100m -Dfile.encoding=UTF-8; see https://kb.sos-berlin.com/x/uYo7B
  switches:
    -c | --curl                            | use curl instead of Java http client 

see https://kb.sos-berlin.com/x/ZqrAAw for more information.

...

  • --http-port
    • Specifies the HTTP port that the Agent is listening to in order to receive requests from a JS7 Controller. This option can be used to indicate which network interface the JS7 Agent should listen to if a hostname or IP address is specified, for example with --http-port=myhost:4445.
    • Without this option being used the port defaults to 4445 and the Agent listens to all available network interfaces.
    • If a port is specified then the following order of precedence applies:
      • First precedence: command line option
      • Second precedence: environment variable JS7_AGENT_HTTP_PORT (see below)
      • Third precedence: use of default value
  • --https-port
    • Specifies the HTTPS port that the Agent is listening to in order to receive requests from a Controller. This option can be used to indicate which network interface the Agent should listen to if a hostname or IP address is specified, for example, with --https-port=myhost:4445.
    • When using the HTTPS protocol for connections from a Controller instance consider additionally allowing the HTTP protocol for local connections as with --http-port=localhost:4445. As the Agent Start Script makes use of an HTTP connection this the protocol has to be in place to allow the Agent to be started, stopped, etc. by its Start Script.
    • Without this option being used the port defaults to 4445 and the Agent listens to all available network interfaces.
    • If a port is specified then the following order of precedence applies:
      • First precedence: command line option
      • Second precedence: environment variable SJS7_AGENT_HTTPS_PORT (see below)
      • Third precedence: use of default value
  • --data-directory
    • Specifies the location of the data directory that usually includes the config, logs, tmp and state sub-directories.
    • This location has to be unique for any Agent instance.
    • If a data directory is specified then the following order of precedence applies:
      • First precedence: command line option
      • Second precedence: environment variable JS7_AGENT_DATA (see below)
      • Third precedence: use of default value JS7_AGENT_HOME/var_<JS7_AGENT_PORT>
  • --config-directory
    • Specifies the location of the config directory for configuration data.
    • This location has to be unique for any Agent instance.
    • Should a configuration directory be specified then the following order of precedence applies:
      • First precedence: command line option
      • Second precedence: environment variable JS7_AGENT_CONFIG_DIR (see below)
      • Third precedence: use of default value JS7_AGENT_HOME/var_<JS7_AGENT_PORT>
  • --sigkill-delay
    • Specifies the delay for terminating job processes on Unix in case the Agent is terminated. A value --sigkill-delay=5 will specify 5 seconds. Default: 3.
    • When the Agent is crashed or is stopped then remaining job processes and child processes will be forcibly terminated by the JS7 - Agent Watchdog.
      • if the --sigkill-delay option specifies a positive, non-zero value
        • send all processes and child processes created by the Agent the SIGTERM signal,
        • wait for the period specified with the --sigkill-delay option,
      • send remaining job processes and child processes the SIGKILL signal.
    • When using JS7 - systemd Service Files for automated Startup and Shutdown with Unix Systems users should consider that --timeout and --sigkill-delay values will count towards the systemd service file's  TimeoutStopSec setting. Users must ensure that the Agent is terminated when the systemd timeout is exceeded.
    • The option is available for Agents running on Unix starting from release 2.7.2, see
      Jira
      serverSOS JIRA
      columnIdsissuekey,summary,issuetype,created,updated,duedate,assignee,reporter,priority,status,resolution
      columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
      serverId6dc67751-9d67-34cd-985b-194a8cdc9602
      keyJS-2148
  • --timeout
    • With the stop and restart commands this option waits for the indicated duration and terminates the Agent including any job processes if the timeout is exceeded.

    • The option accepts a number of seconds or the never value to wait endlessly for jobs to terminate.
    • When using JS7 - systemd Service Files for automated Startup and Shutdown with Unix Systems users should consider that --timeout and --sigkill-delay values will count towards the systemd service file's  TimeoutStopSec setting. Users must ensure that the Agent is terminated when the systemd timeout is exceeded.
  • --kill-script
    • The kill script provides the functionality to kill tasks and any child processes of jobs.

    • Kill scripts are by default provided from the following locations:
      • JS7_AGENT_DATA/work/kill_task.sh for Unix.

      • JS7_AGENT_DATA\work\kill_task.cmd for Windows.

    • This option The option can be used to specify the location of an individual kill script if required.

    • Should an individual kill script be specified then the following order of precedence applies:

      • First precedence: command line option
      • Second precedence: environment variable JS7_AGENT_KILL_SCRIPT (see below)
      • Third precedence: use of default value
    • Starting from release 2.7.2 the option is ignored, see
      Jira
      serverSOS JIRA
      columnIdsissuekey,summary,issuetype,created,updated,duedate,assignee,reporter,priority,status,resolution
      columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
      serverId6dc67751-9d67-34cd-985b-194a8cdc9602
      keyJS-2148
  • --java-options
    • This option can be used to apply Java options for the Agent, e.g. for memory settings, see JS7 - FAQ - Which Java Options are recommended.

    • Without this option being used the Java options default to -Xms100m.

    • In order to specify a number of Java options quotes have to be used like this:
      • --java-options="-Xms100m -Xmx1g"
    • When specifying Java options then the following order of precedence applies:

      • First precedence: command line option
      • Second precedence: environment variable JAVA_OPTIONS (see below)
      • Third precedence: use of default value

...

Code Block
languagebash
agent_4445.sh|.cmd start-container [options]

This The command is used to start the JS7 Agent in a container:

...

The Agent process will terminate.

The Starting from release 2.7.2 the command is deprecated and is replaced by the stop command, optionally for Unix using the --sigkill-delay=0 option.

...

The Agent process is forcibly terminated.

  • The kill command command can be used alternatively as an alias to cancel.
  • The command corresponds to sending a SIGKILL signal with a kill -9 OS command (Unix) or taskkill command (Windows) to the Agent.
  • Should jobs be running then they will be terminated by the JS7 - Agent Watchdog similar to crash of the Agent.

...